CMM-10

1 / 3
CMM-10
Index: WMGBCMM10
Multimeter
Description
Technical Specification
Files
  • Description

    Measure basic parameters with the CMM-10 digital multimeter

    Simple and reliable digital multimeter Sonel CMM-10 designed to test basic parameters such as DC and AC voltage, AC and DC current, frequency, capacitance, duty cycle and temperature. It is a small device with a wide range of applications dedicated to residential and commercial electricians. Due to the possibility of measuring the temperature, heating and air conditioning technicians will also appreciate its advantages. By combining pocket-sized dimensions, intuitive operation and a range of practical functions with an exceptionally good price, the instrument will meet the expectations of beginners and advanced users in the electrical industry and elsewhere. Large digits on the illuminated display ensure that the result can be read at a glance, even in poorly lit areas. As a result, the instrument ensures reliability whatever the operating conditions. It is the ideal solution for every electrician, fitter and maintenance technician.

    11 measuring functions

    • AC and DC voltage
    • AC and DC current
    • resistance
    • capacitance
    • frequency
    • duty cycle
    • temperature
    • diode test
    • continuity

    Basic work tool

    CMM-10 is one of the best solutions for residential and commercial electricians. Additional temperature measurement means that the device can be used by heating and air-conditioning technicians.

    Easy readout

    Thanks to the large digits, the readout of the measured value is extremely fast. The backlit display allows to work in dark areas.

  • Technical Specification

    DC voltage measurement


    Range Resolution Accuracy
    400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
    4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
    40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
    400,0 V 0,1 V ±(1,2% m.v. + 2 digits)
    600 V 1 V ±(1,5% m.v. + 2 digits)

    • Input impedance: 7,8 MΩ

    AC voltage measurement


    Range Resolution Accuracy
    400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
    4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
    40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
    400,0 V 0,1 V ±(1,5% m.v. + 3 digits)
    600 V 1 V ±(2,0% m.v. + 4 digits)

    • Input impedance: 7,8 MΩ
    • Frequency range 50 Hz...400 Hz

    DC current measurement


    Range Resolution Accuracy
    400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
    4000 μA 1 μA ±(1,5% m.v. + 3 digits)
    40,00 mA 0,01 mA ±(1,5% m.v. + 3 digits)
    400,0 mA 0,1 mA ±(1,5% m.v. + 3 digits)
    4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
    10,00 A 0,01 A ±(2,5% m.v. + 5 digits)

    AC current measurement


    Range Resolution Accuracy
    400,0 μA 0,1μA ±(1,5% m.v. + 5 digits)
    4000 μ 1 μA ±(1,8% m.v. + 5 digits)
    40,00 mA 0,01 mA ±(1,8% m.v. + 5 digits)
    400,0 mA 0,1 mA ±(1,8% m.v. + 5 digits)
    4,000 A 0,001 A ±(3,0% m.v. + 7 digits)
    10,00 A 0,01 A ±(3,0% m.v. + 7 digits)

    • Frequency range 50 Hz...400 Hz

    Resistance measurement


    Range Resolution Accuracy
    400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
    4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
    40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
    400,0 kΩ 0,1 kΩ ±(1,2% m.v. + 2 digits)
    4,000 MΩ 0,001 MΩ ±(1,2% m.v. + 2 digits)
    40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

    Capacitance measuremen


    Range Resolution Accuracy
    40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
    400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
    4,000 μF 0,001 μF ±(3,0% m.v. + 5 digits)
    40,00 μF 0,01 μF ±(3,0% m.v. + 5 digits)
    100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

    Frequency measurement


    Range Resolution Accuracy
    5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
    50,00 Hz 0,01 Hz ±(1,5% m.v. + 5 digits)
    500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
    5,000 kHz 0,001 kHz ±(1,2% m.v. + 3 digits)
    50,00 kHz 0,01 kHz ±(1,2% m.v. + 3 digits)
    500,0 kHz 0,1 kHz ±(1,2% m.v. + 3 digits)
    5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
    10,00 MHz 0,01 MHz ±(1,5% m.v. + 4 digits)

    Duty cycle measurement


    Range Resolution Accuracy
    0,1%...99,9% 0,1% ±(1,2% m.v. + 2 digits)

    • Sensitivity: ≥8 V RMS
    • Pulse width: 100 μs –100 ms,
    • Frequency width: 5 Hz do 150 kHz

    Temperature measurement


    Range Resolution Accuracy*
    -20°C...+760°C 1°C ±(3% m.v. + 5°C or 9°F)
    -4°F...+1400°F 1°F ±(3% m.v. + 5°C or 9°F)

    * probe(K type) accuracy not included

  • Files

Basic accessories

Slide 1 of 4

We also recommend