PAT-80
- Description
Safeguarding safety
The Sonel PAT-80 electrical equipment safety testers are used to test the safety of power tools. With its capabilities, you will test key components of an electrical appliance that are responsible for its safety. The PAT-80 compact meter is a proven tool for measuring the resistance of a protective conductor with a current of 200 mA or the insulation resistance with a voltage of 250 V and 500 V.
The instrument is used wherever safety is paramount. It is ideal for situations where you need to check power tools, three-phase appliances or white goods.
Safety guardian on the post
Features
- Extensive measuring system enables:
- protective conductor resistance measurement using current: 200 mA,
- measurement of insulation resistance using voltage: 250 V and 500 V
- measurement of substitute, differential and touch leakage current,
- functional test,
- test of RCD and PRCD switches,
- ...and much more.
- Intuitive user interface.
- Cooperation with a label printer and QR code scanner.
- Robust, compact housing.
- Operation time at rechargeable battery power supply: up to 1 hour
Application
The device is used wherever safety is the most important thing. Ideally suited to situations where it is necessary to check welders, power tools, three-phase devices and household appliances.
Capabilities
Thanks to the extensive measuring part, the device enables comprehensive checking of electrical devices. The touch screen and autoprocedures section make testing quick and efficient.
The meter cooperates with a label printer and QR scanner, which greatly facilitates the recordkeeping of tools. The following printouts are available:
- initial measurement report,
- QR code, where information on performed tests and the parameters of the tested device are saved.
These data can be read and added to the meter memory using the optional QR code scanner.
The whole picture is complemented by a compact and durable housing. It provides instrument protection during both measurements and transport.
Memory
The memory has a tree structure. For each device tested it contains its description, location of measurements, customer data and registration number.
Communication
The meter provides many modes of transmission of measurement results: via USB, LAN and WiFi. In addition, it is possible to upload the results to a USB stick. Dedicated PAT Analysis software allows for data management and also reports preparation - in several versions, depending on the user’s needs. In addition, it is possible to use the PAT Server solution. This system allows you to work in many modes, including:
- smooth data management,
- online upload to server,
- work through a web browser,
- work in task ordering mode,
- storing copies of data on the server.
- Extensive measuring system enables:
- Technical Specification
Measurement functions Range Resolution Accuracy Resistance of protective conductor (PE)None None None I = 200 mA up to 19.99 Ω from 1 mΩ from ±(3% m.v. + 4 digits) Insulation resistance None None None UISO = 250 V / 500 V up to 599.9 MΩ from 1 kΩ ±(5% m.v. + 8 digits) Current (clamp measurement) up to 24.9 A from 1 mA ±(5% m.v. + 5 digits) Visual test ✓ Continuity check of protective conductor (PE) ✓ Insulation resistance measurement at three points ✓ IEC cable test ✓ Functional test Apparent power S up to 3.99 kVA from 1 VA ±(5% m.v. + 3 digits) Active power P up to 3.99 kW from 1 W ±(5% m.v. + 3 digits) Reactive power Q up to 3.99 kvar from 1 var ±(5% m.v. + 3 digits) Power Factor (PF) up to 1.00 0.01 ±(10% m.v. + 5 digits) Current consumption for power measurement up to 15.99 A 0.01 A ±(2% m.v. + 3 digits) THD for voltage and current up to 99.9% 0.1% ±(5% m.v. + 5 digits) Cosφ up to 1.0 0.1 ±(5% m.v. + 5 digits) Leakage current measurement PE leakage current and differential leakage current up to 19.9 mA 0.01 mA ±(5% m.v. + 2 digits) Substitute leakage current up to 19.9 mA 0.01 mA ±(5% m.v. + 2 digits) Touch leakage current up to 4.999 mA 0.001 mA ±(5% m.v. + 3 digits) RCD and PRCD switch test Measurement of RCD parameters according to IEC 61557 up to 300 ms 1 ms ±(2% m.v. + 2 digits) Measurement of RCD tripping current IA for sinusoidal residual current (AC type) up to 30 mA 0.1 mA ±5% IΔn Measurement of power network parameters Voltage up to 265.0 V 0.1 V ±(2% m.v. + 2 digits) Frequency up to 55.0 Hz 0.1 Hz ±(2% m.v. + 2 digits) m.v. – measured value
- Files
- Firmware PAT-80/85/86changelog
- Auto test change
- Improve warning messages
- Adding new states for PRCD measurements