    Take care of safe power tools!    

    The Sonel PAT-820 electrical equipment safety meter is used for measuring the parameters of electrical equipment, including power tools and household appliances, as well as parameters which determine their safe use - resistance of protective conductors, insulation resistance, continuity of connections, leakage currents, power and parameters of RCD switches. The meter presented here is additionally equipped with the Flash test / high voltage test function. The device is intended especially for facility maintenance departments, maintenance services, service companies performing measurements of power tool parameters, hotels and public institutions. The PAT range of meters is proving its worth in areas where ensuring the safe use of power tools is one of the key elements in protecting the user from electrical shock. 

    Data transfer:

    • serial number prefix BJ: USB 2.0, Wi-Fi,
    • serial number prefix MF: USB 2.0.

    Product features

    • advanced measuring unit enabling measurements of:
      • protective conductor resistance
      • of insulation resistance
      • of RCD circuit breaker parameters
      • of equivalent leakage current,
      • of differential leakage current,
      • of touch leakage current
      • of power
      • of power consumption
      • IEC cable test
      • of mains voltage and frequency.
      • flashtest - high voltage test
    • a very intuitive user interface
    • support for label printer and QR code scanner
    • have duty housing (with IP67 flap closed)
    • clear colour touchscreen

    Application

    Digital PAT-820 meter is designed for parameter measurements of all kinds electrical devices, such as power tools, household appliances, etc. The device is dedicated to the facility maintenance departments, companies providing power tool measurement services, hotels and public institutions services. PAT should be used in every place where the safety of using power tools is one of the inseparable elements of taking care of the user’s safety against electric shock.

    Device capabilities

    The PAT-820 device thanks to the advanced measuring unit enables comprehensive testing of power tools. Due to the expanded interface, it enables the recording of large amounts of measurement data, and the use of additional functions to facilitate work. Support for QR code scanner, label printer or communication with PC is not a problem. The measurements are carried out in an intuitive and widely configurable manner.

    Intuitive operation

    The large, touch screen and graphic layout makes work on the device is intuitive and pleasant. The built-in help guides the user when building the correct measurement system. The work related to data records is based on a tree- structure memory that enables the construction of a transparent and extensive database.

    Have duty housing

    Durable case with IP67 protection (with closed lead). It provides reliability during measurement, transport and storage.

  • Technical Specification
    Measurement functions Range Resolution Accuracy
    Resistance of protective conductor (PE)
    I = 200 mA / 10 A/ 25 A up to 19.99 Ω from 1 mΩ from ±(3% m.v. + 4 digits)
    Insulation resistance
    UISO = 100 V / 250 V / 500 V  up to 599.9 MΩ from 1 kΩ ±(5% m.v. + 8 digits)
    Visual test
    Continuity check of protective conductor (PE)
    Insulation resistance measurement at three points
    Durability of insulation (Flash Test)
    IEC cable test
    Fuse test
    Functional test
    Apparent power S up to 3.99 kVA from 1 VA from ±(5% m.v. + 3 digits)
    Active power P up to 3.99 kW from 1 W from ±(5% m.v. + 3 digits)
    Power Factor (PF) up to 1.00 0.01 ±(10% m.v. + 5 digits)
    Current consumption for power measurement up to 15.99 A 0.01 A ±(2% m.v. + 3 digits)
    Leakage current measurement
    PE leakage current and differential leakage current up to 19.9 mA from 0.01 mA ±(5% m.v. + 2 digits)
    Substitute leakage current up to 19.9 mA from 0.01 mA ±(5% m.v. + 2 digits)
    Touch leakage current up to 4.999 mA 0.001 mA ±(5% m.v. + 3 digits)
    RCD switch test
    Measurement of RCD parameters according to IEC 61557 up to 300 ms 1 ms ±(2% m.v. + 2 digits)
    Measurement of RCD tripping current IA for sinusoidal residual current (AC type) up to 30 mA 0.1 mA ±5% IΔn
    Measurement of power network parameters
    Voltage up to 265.0 V 0.1 V ±(2% m.v. + 2 digits)
    Frequency up to 55.0 Hz 0.1 Hz ±(2% m.v. + 2 digits)
    Voltage of PE in power network up to 59.9 V 0.1 V ±(2% m.v. + 2 digits)