PAT-806 digital meters are used to measure the parameters of portable electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power. Specifically the instrument is dedicated to measure the welding equipment.
PAT-806 can be used to test the equipment performed in accordance with standards:
EN 60974-4: Arc welding equipment - Part 4: Periodic inspection and testing.
EN 60745-1: Hand-held motor-operated electric tools. Safety. General requirements.
EN 61029: Safety of transportable motor-operated electric tools. General requirements.
EN 60335-1: Household and similar electrical appliances -Safety -Part 1: General requirements.
EN 60950: Safety of information technology equipment (IT Equipment).
VDE 0404-1: Prüf- und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 1: Allgemeine Anforderungen.
VDE 0404-2: Prüf- und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 2: Prüfeinrichtungen für Prüfungen nach Instandsetzung, Änderung oder für Wiederholungsprüfungen.
VDE 0701-0702 Prüfung nach Instandsetzung, Änderung elektrischer Geräte. Wiederholungsprüfung elektrischer Geräte. Allgemeine Anforderungen für die elektrische Sicherhei. - Technical SpecificationBasic functions:
- measurement of parameters of arc welding machines (EN 60974-4):
- welding machine no-load voltage measurement,
- UP voltage (peak),
- welding circuit leakage current measurement, - measurement of protective conductor resistance with the currents: 200mA, 10A, 25A ( protection class I),
- measurement of insulation resistance – three measurement voltages: 100V, 250V and 500V
- measurement of equivalent leakage current,
- measurement of PE leakage current,
- measurement of residual leakage current,
- measurement of touch leakage current,
- measurement of equivalent leakage current,
- measurement of power,
- measurement of current consumption,
- IEC lead test,
- fuse test,
- check of the L-N circuit test,
- measurement of mains voltage and frequency.
- automatic measurement range selection,
- 990 memory cells for measurement results with option of uploading to a PC through a USB port or printing,
- professional software for data processing and reporting,
- cooperation with a barcode reader and printer,
- supports pendrive flash memory,
- large and clear display with backlight,
- ergonomic operation.
Measurement of protective earth conductor resistance I=200mA
(protection class I)Display range Resolution Accuracy 0,00...0,99 Ω 0,01 Ω ±(4% m.v. + 2 digits) 1,00...19,99 Ω 0,01 Ω ±(4% m.v. + 3 digits) • test current: ≥200 mA for R= 0,2...1,99 Ω
• upper limit adjustable in the 10 mΩ …1,99 Ω range with the 0,01 Ω resolution
• measurement time adjustable in 1...60 s range, with the 1 s resolutionMeasurement of protective earth conductor resistance I=10 A (protection class I)
Display range Resolution Accuracy 0...999 mΩ 1mΩ ±(3% m.v. + 4 digits) ±(3% m.v. + 40 digits)* 1,00...1,99 Ω 0,01Ω ±(3% m.v. + 4 digits) ±(3% m.v. + 40 digits)* *for two-wire measurement
• technical method
• test current: ≥10 A for RŁ0,5 Ω
• limit adjustable in the 10 mΩ …1,99 Ω range with the 0,01 Ω resolution
• measurement time adjustable in 1...60 s range, with the 1 s resolutionMeasurement of protective earth conductor resistance I=25A (protection class I)
Display range Resolution Accuracy 0...999 mΩ 1 mΩ ±(3% m.v. + 4 digits) ±(3% m.v. + 40 digits)* 1,00...1,99 Ω 0,01 Ω ±(3% m.v. + 4 digits) ±(3% m.v. + 40 digits)* *for two-wire measurement
• technical method
• measurement with sinusoidal current of the mains frequency, test current: ≥25 A for R≤0,2 Ω
• limit adjustable in the 10 mΩ …1,99 Ω range with the 0,01 Ω resolution
• measurement time adjustable in 1...60 s range, with the 1 s resolutionMeasurement of L-N circuit resistance
Display range Resolution Accuracy 0...999 mΩ 1 mΩ ±(5% m.v. + 5 digits) 1,00...4,99 Ω 0,01 Ω ±(5% m.v. + 5 digits) • test voltage: 4...8 V AC
• short-circuit current: max. 5 mAMeasurement of insulation resistance
Measurement range according to IEC 61557-2 for:
UN=100V: 100kΩ...99,9MΩ
UN=250V: 250kΩ...199,9MΩ
UN=500V: 500kΩ...599,9MΩUN Display range Resolution Accuracy 100V 0...1999 kΩ 1 kΩ ±(5% m.v. + 8 digits) 100V 2,0...19,99 MΩ 0,01 MΩ ±(5% m.v. + 8 digits) 100V 20,0...99,9 MΩ 0,1 MΩ ±(5% m.v. + 8 digits) 250V 0...1999 kΩ 1 kΩ ±(5% m.v. + 8 digits) 250V 2,00...19,99 MΩ 0,01 MΩ ±(5% m.v. + 8 digits) 250V 20,0...199,9 MΩ 0,1 MΩ ±(5% m.v. + 8 digits) 500V 0...1999 kΩ 1 kΩ ±(5% m.v. + 8 digits) 500V 2...19,99 MΩ 0,01 MΩ ±(5% m.v. + 8 digits) 500V 20,0...599,9 MΩ 0,1 MΩ ±(5% m.v. + 8 digits) • limit adjustable in the: 0.01...9.9 MΩ range with the 0.1 MΩ resolution
• adjustable measurement time: continuous measurement (Cont), or from 4 s to 3 min with 1 s resolution
• automatic discharge of the capacity of the tested device after measurement
• protection against measuring live devices
• output current max. 1.4 mAMeasurement of PE and residual leakage current:
Display range Resolution Accuracy 0,00...3,99mA 0,01mA ±(5% m.v. + 2 digits) 4,0...19,9mA 0,1mA ±(5% m.v. + 2 digits) • limit adjustable in the 0.01...9.9 mA range with the 0.01 mA/0.1 mA resolution
• adjustable measurement time: continuous measurement (Cont), or 1...60 s with 1 s resolution
• in the middle of the measurement time, the meter automatically switches the polarity at the measuring terminal and displays the greater value
• current measurement band 40 Hz...100 kHz (for leakage current) or 20 Hz...100 kHz (for residual leakage current)Measurement of equivalent leakage current:
Display range Resolution Accuracy 0,00...3,99 mA 0,01 mA ±(5% w.m. + 2 digits) 4,0...19,9 mA 0,1 mA ±(5% w.m. + 2 digits) • limit adjustable in the 0.01...9.9 mA range with the 0.01 mA/0.1 mA resolution
• adjustable measurement time: continuous measurement (Cont), or 1...60 s with 1 s resolution
• open circuit voltage 25...50 VMeasurement of touch leakage current:
Display range Resolution Accuracy 0,00...4,999 mA 0,001 mA ±(5% m.v. + 3 digits) • limit adjustable in the 0.01...1.99 mA range with the 0.01 mA resolution
• adjustable measurement time: continuous measurement (Cont), or 4...60 s with 1 s resolutionNo-load voltage measurement for welding machines:
Voltage measurement UR (r.m.s.):Display range Resolution Accuracy 5,0...170,0 V 0,01 V ±(2,5% m.v. + 5 digits)
UP (peak) voltage measurement:
Display range Resolution Accuracy 5,0...240,0 V 0,1 V ±(2,5% m.v. + 5 digits) Welding circuit leakage current measurement IL:
Display range Resolution Accuracy 0,00...14,99 mA 0,01 mA ±(5% m.v. + 2 digits) • current measurement range results from the applied measurement system which is in accordance with EN 60974-4
• upperlimit adjustable in the 0,10 mA…14,90 mA range with 0,1 mA resolution
• adjustable time of measurement: 3 s…60 s with 1 s resolutionMeasurement of power S:Display range Resolution Accuracy 0...999 VA 1VA ±(5% m.v. + 3 digits) 1...3,99 kVA 0,01kVA ±(5% m.v. + 3 digits) • adjustable measurement time: continuous measurement (Cont), or 1...60 s with 1s resolution
Measurement of current consumption:Display range Resolution Accuracy 0,00...15,99 A 0,01 A ±(2% m.v. + 3 digits) • adjustable measurement time: continuous measurement (Cont), or 1...60 s with 1s resolution
Voltage measurement:Display range Resolution Accuracy 187,0…265,0V 0,01V ±(2% m.v. + 2 digits) Display range Resolution Accuracy 45,0 Hz...55,0 Hz 0,1 Hz ±(2% m.v. + 2 digits)
PE network voltage measurement:Display range Resolution Accuracy 0,0...59,9 V 0,1 V ±(2% m.v. + 2 digits)
Conforms to the EMC requirements according to EN 61326-1:2009 and EN 61326-2-2:2006
Electrical safety:- insulation according to: EN 61010-1 and IEC 61557
- measurement category: II 300V acc.to EN 61010-1
- enclosure protection rating acc. to EN 60529: IP40
Other technical specification:
- power supply: 187...265 V, 50 Hz
- load current: max. 16 A (230 V)
- measurement results memory: 990 cells
- data transmission to PC USB
- dimensions: 330 x 235 x 120 mm
- weight: 4,75 kg
- operating temperature:0...+40°C
- storage temperature:-20...+70°C
- humidity: 20...80%
- measurement of parameters of arc welding machines (EN 60974-4):
- Files
- Sonel Reader (current version)changelog
Changes in version 4.0.6.0 compared to the previous one:
- minor bug fixes.
- Firmware PAT-806changelog
- Improving functionality.
- Loss of ability to download data from the meter with programs SonelPAT and Sonel PAT+.